Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Enferm. nefrol ; 17(1): 28-34, ene.-mar. 2014. tab
Artigo em Espanhol | IBECS | ID: ibc-121113

RESUMO

Un conocimiento adecuado sobre la higiene de las manos por parte de los profesionales sanitarios, es el primer paso para la adherencia a cualquier programa de disminución de infección relacionada con la asistencia sanitaria. Objetivo: Evaluar el nivel de conocimientos y percepciones respecto a la higiene de manos entre los profesionales sanitarios de nuestra unidad de Nefrología, y compararlos con los de otra unidad de nuestro centro (Traumatología). Material y método: Estudio prospectivo descriptivo comparativo en 69 profesionales sanitarios. Para evaluar los conocimientos y percepciones respecto a la higiene de manos se utilizó un cuestionario de 26 ítems basado en cuestionarios desarrollados por la Organización Mundial de la Salud. Resultados: 73% utiliza regularmente preparados de base alcohólica para higiene de manos (Traumatología 96,9%, p=0,007). 94% piensa que las manos de los profesionales sanitarios cuando no están limpias son la principal vía de transmisión de gérmenes patógenos (Traumatología: 87,1%, p=NS). 75,7% piensan que el entorno/superficies del hospital es la principal fuente de gérmenes patógenos (Traumatología: 68,8%) y 16% que son los microrganismos ya presentes en el paciente (Traumatología: 25%) (p=NS). Percepciones: 89% consideran alta la repercusión de las infecciones relacionadas con la asistencia sanitaria en el desenlace de la enfermedad (Traumatología: 59,4%, p=0,009). Respecto a las medidas más efectivas para mejorar la higiene de manos destacan la formación de los profesionales sanitarios, recibir retroalimentación regularmente sobre cómo realizar la higiene de manos y que exista un preparado de base alcohólica en cada punto de atención. Conclusiones: Los profesionales sanitarios de Nefrología, al igual que los de Traumatología, en general tienen conocimientos y percepciones adecuados sobre la higiene de manos (AU)


Adequate knowledge about hand hygiene (Hh) by healthcare workers (HCW), is the first step for adhering to any decreased infection related with healthcare (IRHC) program. Aim: To evaluate Hh perceptions and knowledge of HCW in a Nephrology Unit and compare it with another unit in our hospital (Trauma). Methodology: Comparative prospective study in 69 HCW. A 26-itemquestionnaire, based on questionnaires developed by WHO to assess knowledge and perceptions of Hh in HCW was used. Results: 73% regularly use alcohol-based preparations for Hh (Trauma 96.9%, p = 0.007). 94% think that the hands of the HCW when they are not clean are the main route of transmission of pathogens (Trauma: 87.1%, p = NS).75.7% think that the environment / hospital surfaces is the main source of pathogens (Trauma: 68.8%) and16% which are the microorganisms already present in the patient (Trauma: 25%) (p = NS). Perceptions: 89%consider the impact of high IRHC in the outcome of the disease (Trauma: 59.4%, p = 0.009). Regarding the most effective measures to improve the Hh include the formation of HCW, receive regular feedback on how to make the Hh and that a alcohol-based hand rub is present a teach point of care. Conclusions: All healthcare workers have adequate knowledge and perceptions about Hh (AU)


Assuntos
Humanos , Desinfecção das Mãos/métodos , Nefropatias/enfermagem , Conhecimentos, Atitudes e Prática em Saúde , Pessoal de Saúde/estatística & dados numéricos , Diálise Renal/enfermagem
2.
Enferm. nefrol ; 16(4): 223-228, oct.-dic. 2013. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-121712

RESUMO

Objetivo: Evaluar si existen diferencias en el cálculo del Kt/V entre 2 métodos de extracción del BUN post HD. Metodología: Estudio prospectivo comparativo en una cohorte de pacientes en hemodiálisis crónica. Se cuantificó el Kt/V durante dos semanas consecutivas mediante la fórmula de Daugirdas de segunda generación. La extracción de la muestra de sangre para el BUN post hemodiálisis se realizó mediante 2 métodos: disminución del flujo de bomba de sangre a 50ml/min durante 2 minutos, inmediatamente antes de finalizar la sesión (método A); y a los 10 minutos tras fializar la sesión de hemodiálisis (método B). Resultados: 47 pacientes estudiados: 66% homres, edad media de 66±13 años, 51% FAVI, 59,5% hemodiafitración on-line. La media del Kt/V durante las dos semanas del estudio para el método A fue de 1,51 y para el método B de 1,41 (p<0,001). Existieron diferencias estadísticamente significativas según la técnica de hemodiálisis y el acceso vascular entre ambos métodos de extracción. El coeficiente de correlación de Pearson sin embargo, mostró una correlación casi lineal entre las medias del Kt/V de ambos métodos (r=0.954). La diferencia entre ambos métodos fue del 10%. Conclusiones: Existen diferencias signifiativas en l cálculo del Kt/V entre la extracción del BUN post emodiálisis por el método A y B, siendo mayor la osis obtenida por el primer método. Sin embargo, mbas mediciones se correlacionan bien, teniendo en uenta que con la extracción a los 10 minutos se prouce una disminución del 10% sobre el otro método (AU)


Objective: To assess whether there are differences in Kt/V calculation between two post-HD BUN sampling methods. Methodology: comparative prospective study in a cohort of chronic haemodialysis patients. For two consecutive weeks Kt/V was quantified using the second-generation Daugirdas formula. The blood sample for the post-haemodialysis BUN was taken using 2 methods: reduction of blood pump flow to 50ml/min for 2 minutes, immediately before the end of the session (method A); and 10 minutes after the end of the haemodialysis session (method B). Results: 47 patients studied: 66% men, average age of 66±13 years, 51% IAVF, 59.5% online haemodiafitration. The mean Kt/V for the two weeks of the study for method A was 1.51 and for method B was 1.41 (p<0.001). There were statistically significant differences between the two methods according to the haemodialysis technique and vascular access. However, the Pearson correlation coefficient showed an almost linear correlation between the average Kt/V obtained using both methods (r=0.954). The difference between the two methods was 10%. Conclusions. There are significant differences in the Kt/V calculation between post-haemodialysis BUN sampling using method A and B, with the higher dose obtained when the first method is used. However, both measurements are well correlated, taking into account that with sampling after 10 minutes there is a reduction of 10% compared to the other method (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Nitrogênio da Ureia Sanguínea , Nefropatias/enfermagem , Soluções para Hemodiálise , Diálise Renal/enfermagem , Hemodiafiltração/enfermagem , Coleta de Amostras Sanguíneas/enfermagem , Estudos Prospectivos , Estudos de Coortes , Hemodiafiltração/instrumentação , Hemodiafiltração/métodos , Escala Fujita-Pearson
3.
Rev Enferm ; 36(3): 8-12, 2013 Mar.
Artigo em Espanhol | MEDLINE | ID: mdl-23654184

RESUMO

BACKGROUND: The central venous catheter prevalence as a permanent hemodialysis vascular access is growing in the last years. However, there is no consensus in the scientific community about what is the most appropriate lock solution to avoid complications. AIM: To compare the effectiveness and the cost between heparin 20 IU/ml (SH20) lock solution versus usual pattern (UP), consisted on 5% heparin/5000 IU urokinase lock solution in hemodialysis catheters with patency problems. METHODOLOGY: Experimental comparative study. Patients with a permanent hemodialysis central venous catheter with patency problems were included. Catheters were locked with SH20 during 6 sessions and with 5% heparin/5000 IU urokinase during another 6 sessions, depending on the patient. RESULTS: Of 50 patients in our unit, 7 fulfill the inclusion criteria. 42.9% had arterial branch resistance and 57% both branches resistance. Blood flow and venous pressure was similar in both periods. Blood lines reversal percentage was 15.85% using SH20 and 20.61% for UP, not statistically significant in all cases. The lock cost was 1 Euro/session with SH20 and 2.78 Euro/session with UP. CONCLUSIONS: 20 IU/ml heparin as a lock solution for hemodialysis catheters is as effective as the usual patterns but involves less systemic risk to the patient, reduced workload for nurses and lower cost per session.


Assuntos
Anticoagulantes/administração & dosagem , Cateteres Venosos Centrais , Heparina/administração & dosagem , Diálise Renal , Ativador de Plasminogênio Tipo Uroquinase/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resistência Vascular
4.
Rev. Rol enferm ; 36(3): 160-164, mar. 2013. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-113841

RESUMO

INTRODUCCIÓN: En los últimos ańos se ha producido un aumento en la prevalencia de catéteres venosos centrales (CVC) como acceso vascular (AV) permanente para hemodiálisis (HD). Sin embargo, no existe un consenso en la comunidad científica acerca de cuál es la solución de sellado más apropiada para evitar las complicaciones más frecuentes. OBJETIVO: Comparar la eficacia y coste entre el sellado con heparina sódica 20 UI/ml (HS20) frente al sellado con heparina al 5%/uroquinasa 5000 UI, en CVC de hemodiálisis con problemas de permeabilidad. MATERIAL Y MÉTODO: Estudio comparativo experimental. Se incluyeron en el estudio aquellos pacientes portadores de CVC como AV permanente, que presentasen problemas de permeabilidad. Durante seis sesiones de HD los catéteres se sellaron con HS20 y durante otras seis sesiones con la pauta habitual (PH), que consistía en heparina al 5% o uroquinasa 5000 UI, según el paciente. RESULTADOS: De los 50 pacientes de nuestra unidad, siete cumplieron los criterios de inclusión. El 42,9% presentaba resistencia del ramal arterial y el 57% de ambos ramales. El flujo sanguíneo y la presión venosa resultó similar en ambos periodos. El porcentaje de inversión de ramales fue del 15,85% con el uso de HS20 y de 20,61% para la PH, aunque no se alcanzó significación estadística en ningún caso. El coste del sellado fue de 1 €/sesión para la HS20 y de 2,78 €/sesión para la PH. CONCLUSIONES: La HS20, como solución de cebado, resulta igual de eficaz que las pautas habituales pero supone una disminución del riesgo de afectación sistémica, de la carga de trabajo para enfermeria y del coste económico por sellado y sesión


BACKGROUND: The central venous catheter prevalence as a permanent hemodialysis vascular access is growing in the last years. However, there is no consensus in the scientific community about what is the most appropriate lock solution to avoid complications. AIM: To compare the effectiveness and the cost between heparin 20 IU/ml (SH20) lock solution versus usual pattern (UP), consisted on 5% heparin/ 5000 IU urokinase lock solution in hemodialysis catheters with patency problems. METHODOLOGY: Experimental comparative study. Patients with a permanent hemodialysis central venous catheter with patency problems were included. Catheters were locked with SH20 during 6 sessions and with 5% heparin / 5000 IU urokinase during another 6 sessions, depending on the patient. RESULTS: Of 50 patients in our unit, 7 fulfill the inclusion criteria. 42.9% had arterial branch resistance and 57% both branches resistance. Blood flow and venous pressure was similar in both periods. Blood lines reversal percentage was 15.85% using SH20 and 20.61% for UP, not statistically significant in all cases.The lock cost was 1 € / session with SH20 and 2.78 € / session with UP. CONCLUSIONS: 20 IU/ml heparin as a lock solution for hemodialysis catheters is as effective as the usual patterns but involves less systemic risk to the patient, reduced workload for nurses and lower cost per session


Assuntos
Humanos , Masculino , Feminino , Soluções para Hemodiálise/uso terapêutico , /métodos , /enfermagem , Unidades Hospitalares de Hemodiálise , Diálise Renal/métodos , Diálise Renal/enfermagem , Heparina/uso terapêutico , Cateteres/normas , Cateteres/tendências , Cateteres , Resultado do Tratamento , Avaliação de Eficácia-Efetividade de Intervenções , /tendências , Velocidade do Fluxo Sanguíneo/fisiologia
5.
Enferm. nefrol ; 15(4): 271-276, oct.-dic. 2012. tab
Artigo em Espanhol | IBECS | ID: ibc-109002

RESUMO

Objetivo: Comparar la biocompatibilidad entre la hemodiafiltración en línea (HDF) y la hemodiafiltración con reinfusión endógena (HFR). Material y método: Estudio comparativo observacional en una población de 15 pacientes en hemodiálisis crónica elegidos al azar entre los pacientes de nuestra unidad. Se compararon cambios en el perfil hematológico, nivel de PCR y constantes vitales, pre y post hemodiálisis, tras someterse a ambas técnicas de hemodiafiltración. Se comparó las diferencias entre los parámetros estudiados pre y post hemodiálisis en cada técnica. Resultados: Los niveles de plaquetas descendieron más en la HDF (HDF -1,33 vs HFR -19,73 x103/mm3, p=0,005). El nivel de leucocitos disminuyó en la HDF y aumentó en la HFR (HDF -0,46 vs HFR +0,8 x103/ mm3; p=0,006). Respecto a la fórmula leucocitaria hubo resultados dispares: segmentados HDF -1,7 vs HFR +5,4%, p<0,001; linfocitos HDF +1,96 vs HFR -3,62%, p<0,001. Con la HFR disminuyeron menos los niveles de PCR (HDF -0,05 vs HFR -0,001 mg/ dl; p=NS). En lo referente a las constantes vitales, la tensión arterial sistólica descendió más en la HFR que en la HDF (HDF -9,93 vs HFR -10,33 mmHg; p<0,001), a la inversa que la diastólica (HDF -5,2 vs HFR -3 mmHg; p=0,007) y la frecuencia cardiaca (HDF -1,46 vs HFR +1,73 lpm; p=NS). La temperatura corporal aumentó más con la HDF que con la HFR (HDF +0,35 vs HFR +0,06 ºC; p=NS). Conclusiones: Según nuestros resultados la HFR parece más biocompatible que la HDF, probablemente derivado por la reinfusión exógena de la HDF (AU)


Aim: To compare biocompatibility between online hemodiafiltration (HDF) and hemodiafiltration with endogenous reinfusion. Methods: Observational comparative study in a population of 15 chronic hemodialysis patients randomly selected among the patients in our unit. We compared changes in hematological profile, CRP level and vital signs, pre and post hemodialysis, after undergoing both hemodiafiltration techniques. Comparing the differences between the parameters studied before and after each hemodialysis technique. Results: Platelet levels decreased more in the HDF (HDF -1,33 vs HFR -19,73 x103/mm3, p=0,005). Leukocyte levels decreased in the HDF and increased with HFR (HDF -0,46 vs HFR +0,8 x103/mm3; p=0,006). Regarding the leukocyte formula had mixed results: segmented HDF -1,7 vs HFR +5,4%, p<0,001; lymphocytes HDF +1,96 vs HFR -3,62%, p<0,001. With the HFR decreased CRP levels less (HDF -0,05 vs HFR -0,001 mg/dl; p= NS). Regarding vital signs, systolic blood pressure decreased more in the HFR than HDF (HDF -9,93 vs HFR -10,33 mmHg; p<0,001), conversely that the diastolic blood pressure (HDF -5,2 vs HFR -3 mmHg; p=0,007), and heart rate (HDF -1,46 vs HFR +1,73 lpm; p=NS). Body temperature increased more with the HDF that the HFR (HDF +0,35 vs HFR +0,06 ºC; p=NS). Conclusions: According to our results the HFR seems more biocompatible than the HDF, probably derived by exogenous reinfusion of HDF (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Teste de Materiais/métodos , Teste de Materiais/normas , Hemodiafiltração/instrumentação , Hemodiafiltração/métodos , Hemodiafiltração , Reação em Cadeia da Polimerase/métodos , Contagem de Leucócitos/métodos , Contagem de Leucócitos/tendências , Leucopenia/complicações , Leucopenia/diagnóstico , Hemodiafiltração/normas , Hemodiafiltração/tendências , Reação em Cadeia da Polimerase/normas , Temperatura Corporal/fisiologia , Reação em Cadeia da Polimerase/tendências , Temperatura Corporal , Frequência Cardíaca/fisiologia , Leucopenia/fisiopatologia
6.
Enferm. nefrol ; 15(2): 108-113, abr.-jun. 2012. tab
Artigo em Espanhol | IBECS | ID: ibc-100600

RESUMO

La hemodiafiltración en línea es una técnica de diálisis que combina las ventajas de la hemodiálisis de alto flujo (transporte difusivo) y la hemofiltración (transporte convectivo). Esta técnica permite varias alternativas según se incorpore el líquido de reinfusión: pre-dilucional (antes del dializador) y post-dilucional (después del dializador), presentando cada una de ellas ventajas e inconvenientes. El objetivo de este estudio fue comparar distintos parámetros dialíticos y hemodinámicos entre los modos de hemodiafiltración pre y postdilucional. Se realizó un estudio prospectivo transversal en una población en diálisis que ya se trataba con hemodiafiltración en línea, sometiéndose durante 4 semanas a cada una de las modalidades (pre y post-dilucional). Se registraron los valores de: tensión arterial sistólica, diastólica y frecuencia cardiaca pre y post sesión, flujo de sangre, presión venosa, volumen de sangre dializado y volumen de sustitución. La dosis de diálisis se midió mediante dialisancia iónica. Se estudiaron 26 pacientes: 30% mujeres y 70% hombres, con una edad media de 61±13 años. El tiempo medio en tratamiento renal sustitutivo fue de 117±124,45 meses, tiempo medio en hemodiálisis fue de 50±54,38 meses. Los parámetros hemodinámicos no han presentado diferencias significativas entre las dos modalidades estudiadas (pre y post-dilucional). Se obtiene un mayor valor de KT estadísticamente significativo en la técnica de hemodiafiltración post-dilucional precisando ésta un volumen de sustitución de la mitad, en comparación con la modalidad predilucional. Conclusiones: La técnica de hemodiafiltración en línea es bien tolerada en las dos modalidades de infusión. Ante un mismo flujo de sangre, presión venosa y volumen de sangre dializado se consigue una mejor dosis de diálisis en el modo post-dilucional. La hemodiafiltración post-dilucional parece ser una mejor alternativa respecto a la pre-dilucional en relación a los parámetros estudiados siempre que no se tenga en cuenta la problemática de los accesos vasculares. Con dicha técnica logramos mejores resultados de KT precisando la mitad de volumen de sustitución, con el consiguiente ahorro de agua ultrapura. La hemodiafiltración pre-dilucional puede ser una alternativa para aquellos pacientes que no se consiga un flujo arterial alto(AU)


On-line haemodiafiltration is a dialysis technique which combines the advantages of high-flow haemodialysis (diffusive transport) and haemofiltration (convective transport). This technique allows different alternatives depending on how the reinfusion liquid is added: pre-dilution (before the dialyser) and post-dilution (after the dialyser), each of them having advantages and disadvantages. The object of this study was to compare different dialytic and haemodynamic parameters in the preand post-dilution haemodiafiltration modes. A transversal prospective study was conducted of a population in dialysis already being treated with on-line haemodiafiltration, using each of the modes (pre- and post-dilution) with them for 4 weeks. The following values were recorded: systolic and diastolic arterial pressure and cardiac frequency pre- and post-session, blood flow, venous pressure, volume of blood dialysed and replacement volume. Dialysis dosage was measured by means of ionic dialysance. 26 patients were studied: 30% women and 70% men, with an average age of 61±13 years. The average time under renal replacement treatment was 117±124.45 months, and the average time in haemodialysis was 50±54.38 months. The haemodynamic parameters showed no significant differences between the two modes studied (preand post-dilution). A statistically significant higher value for KT was obtained for the post-dilution haemodiafiltration technique, requiring half the replacement volume of the pre-dilution mode. Conclusions: The on-line haemodiafiltration technique is tolerated well in both infusion modes. With the same blood flow, venous pressure and volume of blood dialysed, a higher dialysis dosage was achieved using the post-dilution mode. Post-dilution haemodiafiltration appears to be a better alternative than the pre-dilution mode in terms of the parameters studied as long as the issue of vascular access is not taken into account. Better KT results were achieved with this technique, requiring half the replacement volume, with the resulting saving in ultra-pure water. Pre-dilution haemodiafiltration may be an alternative for patients where a high arterial flow cannot be achieved(AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Hemodiafiltração/métodos , Hemodiafiltração , Hemodinâmica/fisiologia , Diálise Renal/métodos , Diálise Renal , Pressão Arterial/fisiologia , Insuficiência Renal/etiologia , Hemodiafiltração/instrumentação , Hemodiafiltração/tendências , Frequência Cardíaca/fisiologia , Estudos Prospectivos
7.
Rev. Soc. Esp. Enferm. Nefrol ; 14(4): 230-235, oct.-dic. 2011. tab
Artigo em Espanhol | IBECS | ID: ibc-93841

RESUMO

Objetivo: Comparar la tasa de bacteriemias relacionadas con el catéter de hemodiálisis entre el uso de bioconectores y la conexión directa. Metodología: Estudio retrospectivo comparativo transversal durante un periodo de 2 años consecutivos (1 año con conexión directa – Febrero 2009 a Febrero 2010- y 1 año utilizando bioconectores Tego® -Marzo 2010 a Marzo de 2011- ) en los pacientes en hemodiálisis de nuestra unidad que portaban un catéter como acceso vascular permanente. El protocolo de conexión y desconexión de los catéteres durante el periodo de estudio fue el mismo, a excepción de la solución de desinfección empleada: povidona iodada en la conexión directa y clorhexidina al 2% usando bioconectores. Se definió como bacteriemia relacionada con el catéter la aparición de fiebre junto con un hemocultivo positivo, en ausencia de otro foco de infección. Resultados: Se estudiaron 69 pacientes: 36 durante el periodo de conexión directa y 33 durante el periodo del uso de bioconectores. Seis pacientes fueron estudiados durante ambos periodos. La tasa de bacteriemia durante el periodo de conexión directa fue de 24,6 bacteriemias/1000 catéteres-día (9 bacteriemias), mientras que durante el periodo de uso de bioconectores fue de 5,47 bacteriemias/1000 catéteres-día (2 bacteriemias), (p= 0,036). El microorganismo causal más común durante el periodo de conexión directa fue el Staphyloccocus aureus (3 pacientes) junto con el Staphyloccocus coagulasa negativo (3 pacientes). Conclusiones: El uso de bioconectores disminuye de forma significativa la tasa de bacteriemias relacionadas con el catéter de hemodiálisis frente a la conexión directa (AU)


Objective: To compare hemodialysis catheterrelated bacteremia rate between bioconectors use and direct connection. Methodology: Comparative, retrospective and cross-sectional study over 2 consecutive years (one year with direct connection – 2009 February to 2010 February - and 1 year using bioconectors Tego® -2010 March to 2011 March-) in hemodialysis patients in our unit with a permanent catheter as vascular access. Catheters connection and disconnection protocol was the same during the study period, except for the disinfecting solution used: iodine povidone was using in direct connection, and 2% chlorhexidine was using with bioconectors. Catheterrelated bacteremia was defined as onset of fever with a positive blood culture in the absence of another infection source. Results: 69 patients were studied: 36 during direct connection period and 33 during use bioconectors period. Six patients were studied during both periods. Bacteremia rate during direct connection period was 24.6/1000 catheters-day (9 bacteremia), while during the using bioconectors period, bacteremia rate was 5.47/1000 catheters-day (2 bacteremia) (p = 0.036). Staphylococcus aureus (3 patients) and staphylococcus coagulase negative (3 patients) were the most common infectious agents during direct connection period. Conclusions: Use of bioconectors significantly decreases the rate of bacteremia catheter-related in hemodialysis patients versus direct connection (AU)


Assuntos
Humanos , Masculino , Feminino , Bacteriemia/epidemiologia , Bacteriemia/enfermagem , Unidades Hospitalares de Hemodiálise , Diálise Renal/instrumentação , Diálise Renal/enfermagem , Povidona-Iodo/uso terapêutico , Clorexidina/uso terapêutico , /enfermagem , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/enfermagem , Infecções Relacionadas a Cateter/prevenção & controle , Cateteres , Estudos Retrospectivos , Estudos Transversais/métodos
8.
Rev. Soc. Esp. Enferm. Nefrol ; 13(1): 23-28, ene.-mar. 2010. tab
Artigo em Espanhol | IBECS | ID: ibc-79171

RESUMO

El objetivo de este trabajo es evaluar los flujos y resistencias al usar dos tipos de bioconectores luer-lock para catéteres de hemodiálisis. Como objetivos secundarios se pretende evaluar los cambios en la coagulación del sistema, el tiempo empleado en la conexión/desconexión y la opinión de enfermería respecto a su utilización. Material y métodos: estudio experimental aleatorizado en 10 pacientes en hemodiálisis, 5con bioconector Tego® (grupo A) y 5 con BD QSyte® (grupo B), a lo largo de 12 sesiones consecutivas(6 con bioconectores y 6 con conexión directa al monitor). Se estudian las siguientes variables: sociodemográficas, tipo de técnica de hemodiálisis, flujos de sangre, presión venosa, Kt, KtV, coagulación del sistema, tiempo empleado en la conexión/desconexión y la opinión del personal de enfermería. Resultados: La muestra se compuso de 6 mujeres y 4 hombres, con una edad media 62 años y un tiempo medio en hemodiálisis de 4,2 años. En el grupo A, no existieron diferencias estadísticamente significativas entre los flujos de sangre, las presiones venosas y las dosis de diálisis. El grupo B presentó diferencias estadísticamente significativas en los flujos de sangre y en las presiones venosas. No hubo diferencias entre el uso de bioconectores y la conexión directa al catéter en la coagulación del sistema. Los tiempos de conexión y desconexión disminuyeron en ambos grupos. El personal de enfermería opinó quela comodidad en el uso de bioconectores era: mucha (82%), bastante (9%) e igual que sin ellos (9%).Conclusiones: Las tiempos de conexión y desconexión disminuyen con la utilización de bioconectores. El bioconector Tego®, ofrece mejores flujos sanguíneos y menores resistencias venosas (AU)


The aim of this study is to evaluate flows and resistances when using two types of luer lock bioconnectors for haemodialysis catheters. As secondary objectives, the study seeks to evaluate the changes in the coagulation of the system, connection/disconnection time and the opinion of nursing staff on their use. Material and methods: randomized experimental study of 10 patients undergoing haemodialysis, 5with Tego® bioconnectors (group A) and 5 with BD Q-Syte® (group B), over 12 consecutive sessions(6 with bioconnectors and 6 directly connected to the monitor). The following variables were studied: sociodemographic, type of haemodialysis technique, blood flows, venous blood pressure, Kt, KtV, coagulation of the system, time used in connecting/disconnecting and the opinion of nursing staff. Results: The sample comprised 6 women and 4men, with an average age of 62 and an average time on haemodialysis of 4.2 years. In group A, there were no statistically significant differences between blood flows, venous blood pressure and dialysis dose. Group B showed statistically significant differences in blood flows and venous blood pressure. There were no differences between the use of bioconnectors and direct connection to the catheter in the coagulation of the system. Connection and disconnection times were reduced in both groups. Nursing staff considered that the convenience of the use of bioconnectors was: very convenient(82%), quite convenient (9%) the same as without them (9%).Conclusions: Connection and disconnection times fall with the use of bioconnector. The Tego® bioconnector offers better blood flows and lower venous resistance (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Cateterismo/métodos , Diálise Renal/instrumentação , Diálise Renal/métodos , Consentimento Livre e Esclarecido , Diálise/instrumentação , Unidades Hospitalares de Hemodiálise/tendências , Soluções para Diálise/administração & dosagem , Soluções para Diálise/metabolismo
9.
Rev. Soc. Esp. Enferm. Nefrol ; 11(1): 6-11, ene.-mar. 2008. ilus, tab
Artigo em Es | IBECS | ID: ibc-69122

RESUMO

El envejecimiento de la población junto con la pluripatología e inmediatez del comienzo del tratamiento sustitutivo renal supone un gran reto para la enfermería nefrológica. La mayor supervivencia ante ciertas patologías se acompaña de una mayor incapacidad de los pacientes y de una mayor necesidad de cuidados. Nuestro objetivo fue evaluar el grado de dependencia de pacientes en hemodiálisis (HD) hospitalaria y analizar las necesidades de cuidados de enfermería requeridos en función de la misma. Estudio prospectivo descriptivo en 43 pacientes en HD hospitalaria. Para la evaluación del grado de dependencia se utilizó el "Test Delta", que consta de 3 escalas: dependencia en general, deficiencia física y deficiencia psíquica. Se diseñó un registro específico en el que se recogía además: edad, sexo, enfermedad de base, tiempo en HD, Índice de Comorbilidad de Charlson (ICC). Análisis estadístico SPSS 8.0.Se estudiaron 28 hombres (65,1%) y 15 mujeres (34,9%), con una edad media de 61,86 años y un ICC medio de 5,39. Tiempo medio en HD 52,39 meses. El 67,43% presentaba algún tipo de dependencia. Cerca de un 50% de la muestra necesitaba algún tipo de ayuda en cuanto a movilización, deambulación y desplazamiento, aseo y vestido. El 35% precisaba ayuda en la administración de tratamientos y un 70% precisaba mayores cuidados de enfermería. Existe una elevada prevalencia de dependencia de os pacientes en HD hospitalaria, por lo que surge la necesidad de revisar los ratios enfermera/paciente y auxiliar de enfermería/paciente para aportar unos cuidados de mayor calidad (AU)


The aging of the population along with the pluri pathology and immediacy of the beginning of the renal substitute treatment supposes a great challenge for the nephrology nursing. Greater survival before certain pathologies is accompanied by a greater incapacity of the patients and by a greater necessity of cares. Our objective was to evaluate the dependency degree of patients in hospital hemodialysis (HD) and to analyze the required necessities of nursing cares based on the same one. Descriptive prospective study in 43 patients in hospital HD. Dependency degree was evaluated by the “Delta Test”, which consists of 3 scales: general dependency, physical deficiency and psychic deficiency. A specific registry was designed in which it took shelter in addition: age, sex, nephropathy, time in HD, Charlson Comorbidity Index (CCI). Statistical analysis SPSS 8.0.Twenty-eight men (65,1%) and 15 women (34,9%) were studied: mean age 61.86 years, mean CCI 5,39 points and mean time in HD 52.39 months. 67.43% presented some dependency type. Near to 50% of the sample needed some aid type as far as mobilization, de ambulation and displacement, cleanliness and dress 35% needed aid in the administration of treatments and 70% needed greater nursing cares. A high prevalence of dependency of the patients in hospital HD exists, reason why must review patient/ nurse and to patient/ nursing assistant ratios to contribute cares of greater quality (AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Pacientes Domiciliares/estatística & dados numéricos , Diálise Renal/enfermagem , Unidades Hospitalares de Hemodiálise , Insuficiência Renal Crônica/epidemiologia , Carga de Trabalho , Cuidados de Enfermagem/estatística & dados numéricos
10.
J Ren Care ; 33(3): 124-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-19160884

RESUMO

BACKGROUND: Patients with end-stage renal disease (ESRD) present hydro-electrolytic alterations due to the lack of adequate regulation of the internal medium. Of these alterations hyperkalaemia is frequent and produce neuromuscular symptoms, electrocardiographic changes and arrhythmias. Literature affirms that patients with ESRD present less prominent hyperkalaemia-related electrocardiographic changes than those patients with normal renal function. OBJECTIVES: To evaluate electrocardiographic alterations related with potassium in our ESRD patients and to compare the obtained results with those previously reported. METHODS: Descriptive, cross-sectional and prospective study in hospital haemodialysis (HD) patients. Pre- and post-HD serum potassium and other electrolyte concentrations were measured, and simultaneous 12-lead electrocardiogram (ECG) obtained at the first session of the week. An expert evaluated all ECG's. RESULTS: 39 patients were included in the study, 58.9% were women and 41.1% men, with a mean age 67.35 years (24-89). Serum potassium pre-HD range was 2.8 to 7.4 mEq/l (mean 5.07 mEq/L), 29.4% of the sample presented levels > or = 5.5 mEq/l and the most frequent alteration in the ECG was high and peaked T waves in leads V2 to V4. In the hyperkalaemia cases, the mean elevation of T wave was 7 mm. In 2 hyperkalaemia patients there was no elevation of T wave: one T wave was negative (K+ = 6 mEq/L) and another one stayed normal (K+ = 5.6 mEq/L). CONCLUSIONS: The ECG continues to be a good tool of early hyperkalaemia detection, contributing to estimating severity. Patients with ESRD present electrocardiographic alterations similar to the healthy population.


Assuntos
Eletrocardiografia/métodos , Hiperpotassemia/diagnóstico , Falência Renal Crônica/complicações , Diálise Renal , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Cálcio/sangue , Creatinina/sangue , Estudos Transversais , Diagnóstico Precoce , Eletrocardiografia/normas , Feminino , Humanos , Hiperpotassemia/sangue , Hiperpotassemia/etiologia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Avaliação em Enfermagem/métodos , Pesquisa em Avaliação de Enfermagem , Potássio/sangue , Estudos Prospectivos , Diálise Renal/métodos , Índice de Gravidade de Doença , Sódio/sangue , Ureia/sangue
11.
Rev. Soc. Esp. Enferm. Nefrol ; 8(1): 23-26, ene.-mar. 2005. tab, graf
Artigo em Es | IBECS | ID: ibc-038551

RESUMO

Observamos un empeoramiento en la evolución de las heridas quirúrgicas en el postoperatorio del trasplante renal. El comienzo de este problema se presenta al inicio del tratamiento con rapamicina combinado con otros inmunosupresores que ya utilizábamos. Objetivo. Valorar si se corresponde con la observación de enfermería, que el empeoramiento en la evolución de la herida quirúrgica del postrasplante renal, está en relación con el uso de rapamicina como inmunosupresor, añadido a los habituales factores de riesgo. Material y método. Estudio epidemiológico observacional de cohortes retrospectivo. Se estudió aun total de 56 pacientes trasplantados en nuestra unidad, desde el año 1999 hasta el 2003. Se seleccionan30 pacientes con la pauta habitual de inmunosupresión: corticoides, ciclosporina o tacrolimus, micofenolato mofetil, etc. y a 26 pacientes con similar tratamiento, pero asociado a la rapamicina. Resultados. La relación entre los días de exudado de la herida quirúrgica, en el postoperatorio de los pacientes del grupo tratado con rapamicina, es estadísticamente significativa en relación con el grupo que no lo toma, con una p = 0.016 (p< 0,05) en U de Mann Whitney. No siendo significativas las diferencias entre otras variables estudiadas


We note a worsening in the evolution of the surgical wounds in the post-operative kidney transplant. The problem starts at the beginning of treatment with rapamicin combined with other immunosuppressors we already used. Objective. To evaluate whether there is correspondence with the nursing observation that the poorer evolution of the postoperative surgical wound of kidney transplants are related to the use of rapamicinas an immunosuppressor, added to the habitual risk factors. Material and method. Retrospective observational epidemiological study of cohorts. A total 56 patients transplanted in our unit were studied from 1999 to2003. Thirty patients were selected with the usual immunosuppression tendency: corticoids, cyclosporin or tacrolimus, mofethyl micophenolate, etc. and 26patients with a similar treatment, but associated with rapamicin. Results. The relationship between the days of exudation of the surgical wound in the postoperative period of the patients of the group treated with rapamicinis statistically significant in relation to the group that did not take it, with p = 0.016 (p< 0.05)in U by Mann Whitney. The difference between other variables studied was not significant


Assuntos
Humanos , Transplante de Rim/efeitos adversos , Exsudatos e Transudatos , Deiscência da Ferida Operatória/epidemiologia , Sirolimo/efeitos adversos , Imunossupressores/efeitos adversos , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...